Recorded vote
Bylaw reading at the Regular Meeting of Council, January 23, 2017. Defeated 7–8.
Resolution
That Bylaw 32D2017 be read a second time, as amended, in Schedule B, as follows: • on Page 3 of 5, by deleting the proposed map, and substituting with the updated map entitled “New Schedule B map – Bylaw 32D2017”, as distributed at today’s meeting. • on Page 4 of 5, by deleting Section 1 in its entirety and substituting with the following: “Purpose 1 This Direct Control District is intended to: (a) provide for midrise street oriented multi-residential buildings that are sensitive to adjacent low density residential districts; (b) provide appropriate transitions in building heights and setbacks from the adjacent low density residential districts; and (c) adhere building development to slope adaptive principles as topography dictates.” • on Page 4 of 5, by deleting Section 4 in its entirety and substituting with the following: “Permitted Uses 4 The permitted uses of the Multi-Residential – Medium Profile (M-2) District of Bylaw 1P2007 are the permitted uses in this Direct Control District with the exclusion of: (a) Multi-Residential Development - Minor. ” • on Page 4 of 5, by deleting Section 5 in its entirety and substituting with the following: “Discretionary Uses 5 The discretionary uses of the Multi-Residential – Medium Profile (M-2) District of Bylaw 1P2007 are the discretionary uses in this Direct Control District with the addition of: (a) Multi-Residential Development - Minor.” • on Page 4 of 5, by deleting Section 8 in its entirety and substituting with the following: “Building Setbacks 8 (1) Unless otherwise referenced in subsections (2) and (3), the minimum building setback from a property line shared with a street is 3.0 metres. (2) The minimum building setback from a property line shared with a street for a street-oriented multi-residential building is zero metres. (3) Notwithstanding subsection (2), the minimum building setback from a property line shared with a street adjacent to low density residential districts is 3.0 metres. (4) The maximum building setback from a property line shared with a street is 4.5 metres. (5) The minimum building setback from a property line shared with a lane is 13.0 metres. (6) The minimum building setback from a property line shared with another parcel is 1.2 metres.” • on Page 5 of 5, by deleting Section 9 in its entirety and substituting with the following: “Building Height 9 (1) Unless otherwise referenced in subsection (2) the maximum building height on site 1 and site 3 is 20.0 metres. (2) Where a parcel shares a property line with a street, the maximum building height is: (a) 10.0 metres measured from grade within 3.0 metres of that shared property line; and (b) 20.0 metres measured from grade at a distance greater than 3.0 metres of that shared property line. (3) The maximum building height on site 2 is 12.0 metres measured from the top of the curb along 44 Avenue NW adjacent to site 2.” • At the end of the Direct Control District add the following section and number accordingly: “Access No access is permitted from a lane.”
How each member voted
| Seat | Member | Vote |
|---|---|---|
| Mayor | Naheed Nenshi | No |
| Ward 1 | Ward Sutherland | Yes |
| Ward 2 | Joe Magliocca | Yes |
| Ward 3 | Jim Stevenson | Yes |
| Ward 4 | Sean Chu | No |
| Ward 5 | Ray Jones | Yes |
| Ward 6 | Richard Pootmans | No |
| Ward 7 | Druh Farrell | No |
| Ward 8 | Evan Woolley | No |
| Ward 9 | Gian-Carlo Carra | No |
| Ward 10 | Andre Chabot | Yes |
| Ward 11 | Brian Pincott | No |
| Ward 12 | Shane Keating | Yes |
| Ward 13 | Diane Colley-Urquhart | Yes |
| Ward 14 | Peter Demong | No |